Nitinol stents are used to minimize improper dynamic behavior, low twistability and inadequate radial mechanical strength of femoral artery stents. In this study, finite element method (FEM) is used to investigate the effect of crimping and Austenite finish temperature (Af) of Nitinol on mechanical performance of Z-shaped open-cell femoral stent under crimping conditions. Results show that low Af Nitinol has better mechanical and clinical performance due to small chronic outward force (COF), large radial resistive force (RRF) and appropriate superelastic behavior.